Compressor Application Manual
74
VII
• Due to problems of chemical
compatibility, the filter drier normally
used for a system that operates with
R 12, shall be substituted by one
compatible with the blend (see Chapter
VI, item 2).
• Refrigerant fluids (blend) in the system
shall only be charged at the liquid
stage, due to the aforementioned
differences in density.
4 - Alternative refrigerant R 134a
Chosen to replace the R 12 because it has
properties similar to it and does not have the power
to destroy the ozone layer (ODP = 0).
Comments:
• Leakage will cause little (R 134a has GWP)
environmental impact.
• Only recommended for use in new systems
specially designed for its use. The main
reasons are:
– It may require an alteration in the capillary tube
to maintain the system's performance, when
compared to the use of R 12.