Compressor Application Manual
54
Compressor
Type of
Motor
Minimum Sta-
bilizer Capacity
PW, EM
FF BK, FF HBK
FG AK, FG HAK
FF BX, FF HBX
LST
LST
LST/HST
LST/HST
Minimum Trans-
former Capacity
1000 VA
2000 VA
2000 VA
2000 VA
1000 VA
2000 VA
2000 VA
2000 VA
3.3 - EM compressors
EM compressors have been designed to
operate without a starting capacitor.
However, if the use of a capacitor is
necessary, you only need to remove the
copper wire (electric bridge) between
terminal 3 and 4 and connect by
soldering the starting capacitor's
terminals, as shown in the figures below.
Figure 39 - EM relay without capacitor
Figure 40 - EM relay with capacitor
VI
4 - Transformer and Voltage Stabilizer
The capacity of this equipment must be according
to the motor to which it applies. Otherwise, instead
of improving or guaranteeing the normal operation
of the compressor and its electrical components, it
may damage it (see following table).