Compressor Application Manual
20
6 - Start Relay
Remove the compressor relay, check to see if the
start relay is to specification. The relays for high
starting torque compressors, models "X" (e.g.,
FF 8.5BX / FF 10BX and FFI 12HBX), must
notnot
notnot
not have
a bridge (copper wire) between terminals 11 and
13. This connection must be
made through the start capacitor.
For the other models, however,
where the use of the capacitor is
not obligatory, the relays must
have a bridge connecting
terminals 11 and 13.
IV
Figure 10 - Long Relay
Figure 9 - Short Relay
6.1 - Electromechanical relay "F and PW"
6.1.1 - With the relay in the vertical
position, coil downwards,
check if there is continuity
between relay terminals
10 and 11. If not, change
the relay.
Figure 12 - Long F and PW
Relay
Figure 11 - Short F and PW relay
6.1.2 - With the relay in the vertical
position, coil upwards, check if
there is continuity between relay
terminals 10 and 11. If there is,
change the relay and repeat
item 6.1.1
Figure 14 - Long F and PW RelayFigure 13 - Short F and PW Relay
10
11
12
13
10
11
12
13
10
11
12
13
10
11
12
13
10
11
12
13
10
11
12
13