Compressor Application Manual
41
Braze the filter into the condenser and capillary.
Do not unnecessarily heat the body of the filter
dryer, and take great care not to block the tubes.
Install the fast coupling to make a vacuum on
the high pressure side;
The filter dryer must be installed in the vertical
position with the capillary at the bottom
(see figure 29).
This position prevents the desiccant grains from
rubbing and releasing residues. It also helps
equalize a pressure faster (capillary systems).
Figure 29 - Filter Drier
V
The system is now ready to receive
the new compressor. Install it in the
correct position and fix it to the
base. Braze the suction and
discharge tubes to the respective
compressor tubes.
Also braze a tube of approximately
100 mm (3.94”) to the process tube.
Capillary
Condenser
If the refrigeration system has not
been designed to use the compressor's
oil cooling tube (TRO), do not forget
to connect it. Otherwise the
compressor will have a shorter
working life.
Important
!
Brazing - Do not forget to clean
the surface to be brazed well.
Remember: blockage of the
outlet tube will damage the
compressor valve system.
Important
!
Filter Drier