Vue de la page 19
Compressor Application Manual
18
4.6 - Thermostat making noise
Inform the user that a clicking noise is
normal when the thermostat switches on
and off. In any case, please check
whether the thermostat is correctly
installed.
4.7 - Thermostat with loose bulb
Correctly install the thermostat bulb.
4.8 - Thermostat with incorrect bulb
position
Install the bulb according to
manufacturer's specifications.
4.9 - Thermostat with failure
or irregular operation
Substitute the thermostat.
4.10 - Inadequate thermostat
Check if the thermostat model used is
recommended by the manufacturer. If
necessary, consult the manufacturer of
the refrigeration system.
5 - Thermal Protector
5.1 - Incorrect overload protector
Check if the overload protector is as
recommended. If not, change the start
relay and protector kit for that specified.
If necessary, consult the authorized
wholesaler or Embraco.