Compressor Application Manual
39
available for refrigeration professionals to recycle
used refrigerants. More information may be
obtained from the refrigerant wholesalers.
NeverNever
NeverNever
Never use alcohol or other byproducts as a
solvent. They cause corrosion on the compressor
tubes and metallic parts and the electric
insulation becomes brittle.
Only use filters with desiccants suitable for the
type of refrigerant (see table 2, Chapter VI).
4 - How to Clean a used
Refrigeration System
Not all compressor changes require cleaning the
low and high pressure tubes.
Cleaning is recommended in cases where it is
suspected that there are high levels of
contamination of water and residues resulting from
the burnout of the compressor winding. In these
cases:
In R 12 systems, you should make the actual R 12
or R 11, or the degreaser R 141b, or VERTREL XF
circulate when it is liquid.
In systems operating with R 134a, you may use the
R 141b degreaser or VERTREL XF for cleaning.
To protect the environment and reduce expenses
when changing compressors, fluid for cleaning the
unit's components must circulate in closed circuits.
At this stage when changing the compressor, the
return line shall be disconnected from the
compressor and the capillary disconnected from
the filter drier.