Compressor Application Manual
31
19.3 - Compressor with current leakage
to the housing
Connect the megohmeter terminals to
the common pin of the hermetic
terminal and grounding terminal of the
compressor. With 500V/DC voltage,
the reading should show a resistance
of over 2MΩ. If there is no
megohmeter, use a test lamp as
follows: connect one of the test points
to the common pin of the hermetic
terminal and another to the grounding
terminal of the compressor. If the bulb
lights up, change the compressor.
IV
Figure 24 - PW/F/EG Compressor Coil Test
If the lamp lights up in any
of the cases the compressor must
be changed.
C
P
A
C
PA
Figure 24.a - EM Compressor Coil Test
If the lamp lights up in any
of the cases the compressor must
be changed.