Compressor Application Manual
22
6.3 - PTC Relay
With the help of an ohmmeter, measure
the ohmic resistance between terminals
2 and 3. At room temperature, the figures
must be near those in the above table:
IV
EM relay with external electrical bridge
In the same way as with relays in the PW and F/EG
groups, the EM compressor relays are suitable for
using a start capacitor (fig.18).
A starting capacitor in applications where this
component is required, must be used by removing
the bridge between the terminals 3 and 4 and
connecting the capacitor between these terminals
(see fig. 18 and 19). This modification does not
alter the performance characteristics of the relays.
Figure 18 - Standard starting
relay
Electrical
Bridge
Figure 19 - With capacitor
Figure 17 – PTC
1
2
4
3
Relay – PTC*
Ohm Resistance
(! = OHMS)
8EA1BX
7M4R7XXX / 8M4R7XXX / 8EA14CX
8EA4BX / 8EA3BX / 8EA21CX
8EA5BX
7M220XXX / 8M220XXX / 8EA17CX
2,8 a 5,2 !
3,8 a 5,6 !
3,5 a 6,5 !
14 a 26 !
17,6 a 26,4 !
* The
(X)(X)
(X)(X)
(X) can be a number or a character.