Compressor Application Manual
29
17 - Refrigerant Fluid
17.1 - Expansion of refrigerant
in evaporator
Explain to the customer that it is
normal that there is a certain noise
when expansion occurs. The noise
level varies according to the type of
evaporator and refrigerator.
17.2 - Excess refrigerant fluid
charge in the refrigerator
Check if there is condensation on
the suction line, outside the cabinet.
If so, install the correct refrigerant
fluid charge.
17.3 - No refrigerant fluid charge
An irregular layer of ice forms in the
evaporator. Install a new refrigerant
fluid charge in the system.
17.4 - Leakage of refrigerant fluid
Check the leakage point, remove it or
change the part. Install a new
refrigerant fluid charge.
18 - Use of Expansion Valve
18.1 - High starting torque
Check if the refrigeration system uses
an expansion valve. If so, Embraco
IV