Vue de la page 39
Compressor Application Manual
38
V
3 - How to Remove the Filter Drier
Remember that changing the compressor also
requires a change of the filter drier, in the order
as follows:
Slowly warm the soldering region of the
capillary with the filter dryer and, at the same
time, pull the capillary with pliers, using
moderate force not to break it inside the filter
drier. Preferably, during the removal of the
capillary, make nitrogen circulate to prevent
the capillary end from blocking up.
After cooling, close off the end of the capillary
tube with a rubber plug.
Important comments
Another procedure that normally prevents
blocking the capillary is to remove the end that
had been brazed to the filter drier. Using a file,
make a small groove around the capillary and
bend it until it breaks. Nevertheless, in cases of
successive re-operations of the same system, the
shortening of the tube will significantly alter the
capillary flow and jeopardize the performance of
the refrigeration system.
When removing the filter, you must not heat it
unnecessarily otherwise water retained in it will
enter the system piping.
Emission of CFCs (R 12, R 11 etc.) into the air
affects the ozone layer. Until a more effective
solution appears for collecting, recovering,
recycling and neutralizing the harmful effect of the
refrigerant, please attempt not to release CFCs
into the environment. Proper equipment is
Vue de la page 39